State-of-the-art Sterilisation Unit
Laser Assisted Root Canal Treatment

Root canal treatment is a common dental procedure used to save an abscessed or infected tooth and prevent the need for dental implants or bridges. This treatment stops the blood supply and removes the nerve connected to the infected tooth. It involves cleaning and sterilization of the root canal and removal of the tissue of the canal. This entire procedure sounds scary and many people flinch back in fear when they hear the term “root canal”.
We at dr32 have now started using new technology –Laser assisted root canal therapy to perform the procedure. The laser treatment works by producing non-thermal photoacoustic shock waves – i.e. it uses two laser wavelengths Er: YAG and Nd: YAG,/Diod making the best use of the unique laser-tissue interaction features of each wavelength. Er: YAG induces shock waves in the cleaning solutions and Nd:YAG has a superior bactericidal effect. The canals and accessory canals are cleaned and the dentinal tubules are free of a smear layer (debris consisting of bacteria and infection). When the laser is introduced into the tooth access, you see the solution pulsating with the debris of dead tissue streaming out of the access hole making the canals free of dead tissues.
Laser Assisted Minor Oral Surgery

Laser surgery has emerged as an established method in advanced medicine. Laser-induced
remote tissue treatment provides a number of advantages: controllable coagulation and cutting
of surgical tissues with wavelength tissue-specific cutting efficiency
The reason for this transition is simple: many procedures can be executed more efficiently and
with less morbidity using lasers when compared with scalpel, electrocautery or high frequency
devices.
Laser Assisted Tooth Whitening

Laser-assisted Tooth Whitening uses laser beam to accelerate release of free radicals within the bleaching gel to decrease time of whitening procedure. Lasing is also capable of minimizing post-bleaching hypersensitivity, loss of enamel microhardness and gingival irritation due to lack of hydrogen peroxide use we have the best facilites to cater Laser Assisted Tooth Whitening in cochin
Laser Assisted Gum Surgery

Laser-assisted new attachment procedure (LANAP) is a surgical therapy for the treatment of periodontitis, intended to work through regeneration rather than resection. This therapy and the laser used to perform it have been in use since 1994. This procedure is a protocol that deals with inflammation, the infectious process, occlusion, tooth mobility, and an osseous component. It is a rather simple, but elegant, protocol that tips the scales in favor of periodontal regeneration. Dr32 has one of the best laser assisted dental unit in cochin
Lingual Orthodontics

As the numbers of adult patients who seeking orthodontic treatment are increasing rapidly, the demand of aesthetic orthodontics has been increased, many appliances have been introduced to the market. The ultimate of which are appliances bonded to the lingual surfaces of the teeth. The current mini review is provided on the historical development of lingual appliances, advantages as well as disadvantages and cases selection. Dr32 has one of the best Lingual Orthodontics department in cochin
Dental Aligners

Clear orthodontic aligners are an alternative to traditional braces that are used to move your teeth and transform your smile without much interference to your daily life. They are removable trays made of a clear plastic material that is essentially invisible.
When using aligners, a sequence of slightly different trays is custom-made to fit over your teeth. You must wear each one 20 hours a day for two weeks before changing to the next in the series. The aligners are computer generated, designed by state-of-the-art techniques based on models and images of your own teeth. They work because slight changes in the sequential aligners gradually shift your teeth. If they are worn consistently, the process takes from six months to two or three years. Come to dr32 clinic for clear aligners in cochin
Class-B Autoclave

Microbial threats in laboratories and medical practice in general is a growing concern today. Meanwhile the science and technology of in-clinic sterilization process is seeing huge advancements as well. A successful sterilization happens only when all viable microorganisms including many of the highly resistant bacterial spores are destroyed. Only class B autoclaves are capable of performing to this level. Class B autoclaves cover the broad spectrum of pathogens that is likely to be found in dental, ophthalmic and any surgical procedure. This is the only clinically acceptable means of sterilizing reusable instruments used between patients. Class B autoclaves are designed to sterilize using elevated temperatures of 121 to 134 degree centigrade under pressure of 15 to 30 psi and it has a maximum holding time of 30 minutes. None of the other methods of sterilization matches the cleanliness and effectiveness of a class B. it can sterilize solid, hollow and porous instruments whether in wrapped or unwrapped state. Class B has yet another major safety feature. It uses active forced air removal using an in-built vacuum pump. This removes the air from the load prior to the chamber being pressurized with steam. At Dr. 32 we use Class-B Autoclave for your total protection.
Ultrasonic Washer

Ultrasonic cleaning reduces direct contact with contaminated instruments. It creates cavitations which forms billions of bubbles which are bombarded against the instruments to produce a cleaning turbulence. This is much more efficient than manual scrubbing. All instruments can be cleaned ultrasonically. At Dr. 32 we use ultrasonic washer for optimum cleaning results.
Deionizer

We use a Deionizer to reduce the minerals present in the water. This process prepares the ideal water for autoclaves and other devices. The specific conductance of the water is according to the value suggested by EN 13060 norms.
Assistina

Assistina cleaning process assures automatic internal cleaning of the spray channels and transmission parts using W&H Active fluid. Compressed air is blown through spray channels and transmission parts. Secondly, external parts of the instrument are automatically cleaned with W&H Active fluid. Thirdly, the transmission parts are lubricated with W&H Service Oil F1. The most efficient way to clean inside and outside at the same time.
Needle Burner & Syringe Destroyer

At Dr.32 we believe that it is important to always use disposable needle and it is more important to destroy them after use. After use, the contaminated syringe with needle is inserted in the destroyer which generates a high temperature above 1600 degrees centigrade, thereby completely burning the needle and reducing it to ashes in just 2 seconds.
Instrument Pouch Sealing Machine

At Dr.32, we follow a world-class sterilization protocol. No sterilization is 100% safe or complete if the autoclave treatment for sterilization is not done with the instruments enclosed in a special sealed pouch. We use the top of the line Euronda machine for pouch sealing. In this process the instruments are placed in the autoclave within a sealed pouch. Then the autoclave sterilization takes place. The instruments remain sealed till it reaches the doctor, and it is opened only by the doctor under sterile conditions in front of the patient.